A static session between a base with a known coordinate and a rover is solved as one baseline over the whole session, from precise orbits. This is what RTK on /positioning reports as the coordinate of a static session, and what the local network mode of /campaign uses for every baseline. The epoch-by-epoch solution with broadcast orbits (the track on the map) is described on Epoch-by-epoch RTK; it is used for the coordinate only when precise orbits are not out yet (about a day after the observations).
Observation model
Each station is first modelled on its own, as in PPP but in one batch: precise orbit and clock at the emission time (taken from the pseudorange, which synchronises the receiver clock), the periodic relativistic clock term, Earth rotation, the a priori troposphere, and the station corrections — satellite and receiver antenna phase centres (IGS20), phase wind-up, solid-earth tides and ocean tide loading. Between the two stations, single differences of the ionosphere-free carrier phase are formed per satellite and the receiver-clock difference of each epoch is eliminated:
Eliminating Δdt epoch by epoch is the same as forming double differences with their full correlation, without choosing a reference satellite. Satellite clocks cancel. The ionosphere-free combination removes the first-order ionosphere, so baseline length is not limited by it. Estimated: the rover's coordinates, the zenith delay of both stations (piecewise linear, 1-hour nodes) and their north/east gradients (piecewise linear, 24-hour nodes), and one ambiguity per single-difference arc, pre-eliminated per baseline. The base is held at its coordinate (σ 0.1 mm). The a priori troposphere is VMF3 from TU Wien's grids (GPT3 where they are not out yet); see Shared models.
Pre-processing
- Code outliers against the epoch's median code clock of the station.
- Cycle slips from the Melbourne–Wübbena wide lane and a prediction of the geometry-free phase along the arc. There is no clock-dependent test: satellite clocks cancel here, and interpolating 5-minute clocks must not raise slips.
- Every slip, and every gap longer than 180 s, starts a new ambiguity (no repair). Arcs shorter than 10 minutes are dropped.
Integer ambiguities
The wide lane comes from the Melbourne–Wübbena single-difference arc means, after removing the baseline's receiver wide-lane bias; it is fixed when within 0.25 cycles of an integer with a σ below 0.1 cycles. The narrow lane is then resolved on the ionosphere-free float solution with LAMBDA (ratio test 3, partial fixing), as double differences within each constellation, for arcs of at least 30 minutes. Fixed ambiguities enter as constraints and the baseline is solved again; this is done twice. Residuals beyond 4 σ̂ are rejected and the solution repeated, up to three times.
Constellations
Baselines use GPS and Galileo. Between different receiver makes, BeiDou and GLONASS carry biases that do not cancel in static double differences: about 1 cm in height for BeiDou, 5–10 mm for GLONASS (its frequency-dependent inter-channel biases). BeiDou can be chosen in the advanced settings; it is then processed with float ambiguities. GLONASS is not used.
The PPP check
Each station is also positioned on its own by PPP, and the two positions are differenced. When that vector and the double-difference vector disagree by more than 10 mm (3-D), the double differences are taken to carry wrong integers — this happened on single long baselines — and the PPP difference is reported instead, with its own uncertainty. The result says which of the two it is.
Reported uncertainty
The formal covariance of a day of double differences says a millimetre or two, which is too optimistic. The report gives the 95 % uncertainty from that covariance — 2.45 σ for the horizontal radius, 1.96 σ vertically — but never less than 6 mm horizontally and 10 mm vertically, the most the validation below supports. It is relative to the base: the error of the base coordinate adds to it.
Local network mode (/campaign)
Files are grouped into sessions by UTC day. In each session every point is tied to the chosen reference point by a baseline solved as above; in sessions with at most five other points, the baselines between those points are added as well, so that their loops can be checked. Each session's baselines are adjusted by least squares with the reference held at its mean PPP position, which gives:
- the a-posteriori variance factor σ̂₀ and its χ² test (α = 0.05);
- data snooping with Baarda's w-test (α₀ = 0.001, critical value 3.29): the worst failing baseline is dropped and the adjustment repeated, but never one a point depends on;
- loop misclosures.
The adjusted daily positions then go through the same coordinate-series fit as the daily PPP positions of /campaign.
Defaults
| Setting | Default | Note |
|---|---|---|
| Orbits and clocks | Precise (same product chain as PPP) | Without them: epoch-by-epoch RTK, said so in the result |
| Constellations | GPS, Galileo | BeiDou can be chosen; GLONASS is not used |
| Signals | Ionosphere-free GPS L1/L2, Galileo E1/E5a | |
| Elevation cut-off | 3° with VMF3, 10° otherwise | |
| Sampling of the adjustment | 30 s | |
| Phase σ at zenith | 3 mm (undifferenced ionosphere-free) | Weight σ² / sin²e |
| Base | Held at its coordinate (σ 0.1 mm) | |
| Zenith delay | Piecewise linear, 1 h nodes, at both ends | A priori σ 1 m |
| Gradients | Piecewise linear, 24 h nodes, at both ends | A priori σ 1 cm |
| Arcs | New ambiguity after a slip or a gap > 180 s; arcs < 10 min dropped | |
| Wide lane | |fraction| ≤ 0.25 and σ ≤ 0.1 cycles | |
| Narrow lane | LAMBDA, ratio ≥ 3, float σ ≤ 0.15 cycles | Arcs of at least 30 min; two fixing rounds |
| Residual screening | 4 σ̂, up to 3 re-solves | |
| PPP check | > 10 mm (3-D) apart → the PPP difference is reported | |
| Reported 95 % uncertainty | At least 6 mm horizontal, 10 mm vertical | Relative to the base |
Where it is in the code
Source
-
src/positioning/dd-network.ts— solveDdNetwork and prepareDdStation: zero-difference model, pre-processing, single differences with the epoch clock eliminated, troposphere and gradient nodes, wide-lane and narrow-lane fixing, normal equations -
src/analysis/baseline-selection.ts— independent baselines (OBS-MAX or shortest spanning tree) for networks -
src/analysis/baseline-network.ts— adjustBaselineNetwork: least-squares adjustment of baseline vectors, σ̂₀ and χ² test, Baarda’s w-test, loop misclosures -
src/positioning/ppp-corrections.ts— the station corrections both ends share with PPP (antenna, wind-up, tides, ocean loading) -
src/positioning/lambda.ts— the integer search
Tests
-
test/dd-network.test.ts— baseline selection; a simulated network recovered to the millimetre with ambiguities fixed, zenith wet delays recovered, constraint-free normal equations -
test/baseline-network.test.ts— the adjustment: exact recovery, σ̂₀² ≈ 1 and a passing χ² with correct weights, a 5 cm blunder found and shown by the loops
Validation
13 EPN baselines from 0.1 to 1992 km, seven days each (GPS week 2297, January 2024), each day solved as the site solves it and compared with EUREF's weekly solution. 3-D RMS of the rover position (re-run 16 November 2026):
| Baseline | Length (km) | 3-D RMS (mm) |
|---|---|---|
| WTZR–WTZS | 0.1 | 1.8 |
| MET3–METG | 2.8 | 2.2 |
| IENG–TORI | 5.6 | 2.3 |
| CEBR–MADR | 10.4 | 8.9 |
| BADH–FFMJ | 15.8 | 4.2 |
| AXPV–MARS | 23.7 | 6.7 |
| EIJS–WARE | 31.9 | 2.1 |
| MATE–SNIK | 53.0 | 4.8 |
| IGMI–GARI | 128 | 7.6 |
| DGOR–SNIK | 242 | 6.6 |
| ONSA–MAR6 | 470 | 5.4 |
| JOZE–PADO | 1000 | 9.2 |
| IGMI–LERI | 1992 | 11.2 |
- Up to 50 km the rover is within 1.8–8.9 mm (3-D RMS), five of the seven baselines within 5 mm, the error almost all vertical; over all 13 within 1.8–11.2 mm.
- CEBR–MADR is −7.8 mm in height every day. It shrinks with a higher cut-off (3°: −7.8, 5°: −3.5, 10°: −2.1 mm), so it comes from MADR's lowest elevations; on other baselines a higher cut-off is worse (BADH–FFMJ −2.3 mm at 3°, −6.5 mm at 10°, −16.0 mm at 15°), so 3° stays.
- Double differences alone reached 51–57 mm on the 128 and 242 km baselines (wrong integers); the PPP check is what brings those in.
- Wettzell, WTZR to WTZS (68.698 m, 24 h): the rover within 1.5 mm horizontally and 3 mm in height of EUREF's coordinate.
- Network mode at the Wettzell observatory (WTZR as reference; WTZZ 1.6 m and WTZS 69 m away; three receiver makes; six days in January 2024): mean adjusted positions within 0.7–1.9 mm of EUREF's weekly solution in each component, loops closing within 0.4–3.9 mm.
More on the validation page and in Methods.